Tom Neltner, J.D. is the Chemicals Policy Director
This is the first in a series of blogs evaluating various aspects of EPA’s December 2020 revisions to the Lead and Copper Rule (LCR) and what they may mean for accelerating lead service line (LSL) replacements. The blogs cover: 1) the new service line inventory; 2) three new LSL notices; 3) environmental justice implications; 4) communicating health effects of lead; 5) economic implications; and 6) sampling and trigger/action level.
Note that President Biden’s Executive Order on Protecting Public Health and the Environment and Restoring Science to Tackle the Climate Crisis directs agencies to review the former administration’s regulations and actions, including the Lead and Copper Rule.
The backbone of the revised LCR is a new service line inventory[1] that all public water systems, whether large or small, rural or urban, must develop by January 2024 unless they can demonstrate that they have no LSLs. If properly designed and implemented, the inventory should transform how utilities, communities and states approach LSLs by moving from rough estimates to a data-driven approach that allows water systems to identify what is known and not known about the service lines, communicate that information to the public, and establish LSL replacement priorities.
Unfortunately, EPA has included an unfortunate and absurd new detail in the inventory that requires systems to categorize service lines that contain a two-foot piece of lead pipe, often known as a gooseneck, as “Non-lead.” We anticipate that the absurdity of calling a lead pipe “Non-lead” will undermine the inventory’s credibility and effectiveness.
What is the new service line inventory and how is it used?
By January 2024, water systems must submit a service line inventory to the state and make it publicly accessible pursuant to 40 CFR § 141.84(a). To develop the inventory, they must assign all service lines, regardless of ownership, for the portions on public or private property to one of four categories:
- Lead: where a portion of the service line is made of lead (excluding lead connectors, such as goosenecks, as explained below). We presume this includes lead-lined pipe.
- Galvanized Requiring Replacement: where a portion of the service line is galvanized iron or steel.[2] If the system can determine that the galvanized pipe was never downstream of an LSL (or lead connector, such as a gooseneck[3]), then it is essentially a galvanized pipe not requiring replacement and can be categorized as “Non-lead.”
- Non-lead: where the line is determined not to be “Lead” or “Galvanized Requiring Replacement” (see discussion below for lead connectors). Our understanding is that systems could assume service lines installed after the 1986 federal ban on lead pipe are “Non-Lead.”
- Lead Status Unknown: where it has not been determined if the service line met the SDWA Section 1417 definition of “Lead-free” at 42 U.S.C. § 300g-6. We presume this means that solder or flux must be less than 0.2% lead and other wetted surfaces must be less than 8% from 1986 to 2013 and less than 0.25% for 2014 to present.[4]
Under these requirements, a service line is classified as an LSL if it is in the “Lead” or “Galvanized Requiring Replacement” categories.[5]
Read More »