<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Nano “Trojan Horse” Study Gets Top Billing</title>
	<atom:link href="http://blogs.edf.org/nanotechnology/2008/03/07/nano-%e2%80%9ctrojan-horse%e2%80%9d-study-gets-top-billing/feed/" rel="self" type="application/rss+xml" />
	<link>http://blogs.edf.org/nanotechnology/2008/03/07/nano-%e2%80%9ctrojan-horse%e2%80%9d-study-gets-top-billing/</link>
	<description>Our experts&#039; views on chemical and nano news</description>
	<lastBuildDate>Tue, 16 Mar 2010 15:07:26 -0700</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Cal Baier-Anderson</title>
		<link>http://blogs.edf.org/nanotechnology/2008/03/07/nano-%e2%80%9ctrojan-horse%e2%80%9d-study-gets-top-billing/comment-page-1/#comment-17</link>
		<dc:creator>Cal Baier-Anderson</dc:creator>
		<pubDate>Mon, 10 Mar 2008 14:18:15 +0000</pubDate>
		<guid isPermaLink="false">http://blogs.edf.org/nanotechnology/2008/03/07/nano-%e2%80%9ctrojan-horse%e2%80%9d-study-gets-top-billing/#comment-17</guid>
		<description>Good question! 

Yes, equimolar amounts of metals were tested.  According to the &lt;a href=&quot;http://pubs3.acs.org/acs/journals/supporting_information.page?in_manuscript=es062629t&quot; rel=&quot;nofollow&quot;&gt;supporting information&lt;/a&gt; provided by the authors on the ES&amp;T website (subscription required), the following concentrations were tested, noting that since there are no known titania salts soluble in neutral, aqueous media, titanium was not tested in this component of the study:

FeCl3 was tested at 0.371 mM, corresponding to 30 ppm Fe2O3,
MnCl2 was tested at 0.393 mM, corresponding to 30 ppm Mn3O4, and 
CoCl2 was tested at 0.374 mM, corresponding to 30 ppm Co3O4.</description>
		<content:encoded><![CDATA[<p>Good question! </p>
<p>Yes, equimolar amounts of metals were tested.  According to the <a href="http://pubs3.acs.org/acs/journals/supporting_information.page?in_manuscript=es062629t" rel="nofollow">supporting information</a> provided by the authors on the ES&amp;T website (subscription required), the following concentrations were tested, noting that since there are no known titania salts soluble in neutral, aqueous media, titanium was not tested in this component of the study:</p>
<p>FeCl3 was tested at 0.371 mM, corresponding to 30 ppm Fe2O3,<br />
MnCl2 was tested at 0.393 mM, corresponding to 30 ppm Mn3O4, and<br />
CoCl2 was tested at 0.374 mM, corresponding to 30 ppm Co3O4.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Steven Fowkes</title>
		<link>http://blogs.edf.org/nanotechnology/2008/03/07/nano-%e2%80%9ctrojan-horse%e2%80%9d-study-gets-top-billing/comment-page-1/#comment-14</link>
		<dc:creator>Steven Fowkes</dc:creator>
		<pubDate>Sat, 08 Mar 2008 18:17:34 +0000</pubDate>
		<guid isPermaLink="false">http://blogs.edf.org/nanotechnology/2008/03/07/nano-%e2%80%9ctrojan-horse%e2%80%9d-study-gets-top-billing/#comment-14</guid>
		<description>Was a oxidative-damage comparison made with an equimolar exposure of the metal oxide as a simple salt?</description>
		<content:encoded><![CDATA[<p>Was a oxidative-damage comparison made with an equimolar exposure of the metal oxide as a simple salt?</p>